Floor elevation at non-egress exterior doors: not more than 8.25 inches below the top of threshold

Virginia USBC 2021 Amendment 18 (IRC R311.3.2)

Description

Doors other than the required egress door shall be provided with landings or floors not more than 8.25 inches below the top of the threshold, provided the door does not swing over the landing.

Why this exists

Allows steps down to porches and patios at secondary doors while preventing dangerously-elevated thresholds. The 8.25" max matches the IRC stair-riser maximum so a single-step transition is code-compliant.

Measurements

PropertyOperatorValueUnitNote
maxDropmax8.25inFloor-to-threshold drop at non-egress exterior doors (no swing over landing)

Categories

Life safety

Applies to

  • Jurisdiction: Virginia

Source

Virginia DHCDauthoritative
2021 Virginia Construction Code (Part I of USBC) (2021)
Section: Amendment 18 (IRC R311.3.2)
Published 2024-01-18 · last verified 2026-05-10