Exterior wall fire separation distance

IRC R302.1

Description

Exterior walls within 5 feet of a property line must be 1-hour fire-resistance-rated. Openings in walls within 3 feet are prohibited; openings 3-5 feet must be fire-rated.

Why this exists

Adjacent dwellings need a fire-rated separation to slow fire spread between properties.

Measurements

PropertyOperatorValueUnitNote
minFireResistanceDistancemin5ftDistance below which 1-hr rating required
minOpeningSetbackmin3ftMin distance to nearest opening

Categories

Life safetyStructure

Source

ICCno manifest entry
International Residential Code (2024)
Section: R302.1
Published 2024-01-01 · last verified 2026-05-09