Skip to main content
Almost an Architect
Current page: HUD FHA Design Manual Chapter Six §6.4
GuidelineRecommended

Toilet side grab-bar reinforcement: 36 inches from back wall, 33-36 inches above floor

HUD FHA Design Manual Chapter Six §6.4

Description

Reinforcement for a future toilet side grab-bar shall be located so the grab-bar can be installed 33-36 inches above the floor, extending 36 inches from the back wall. Toilet centerline must be 16-18 inches from the side wall holding the bar.

Why this exists

ANSI A117.1 §604.5.1. The 16-18" toilet centerline + 36"-long side bar are the geometry that lets a seated user with limited mobility transfer from a wheelchair.

Measurements

PropertyOperatorValueUnitNote
sideBarLengthmin36inSide grab-bar reinforcement length
heightMinmin33inGrab-bar height above floor (min)
heightMaxmax36inGrab-bar height above floor (max)
centerlineMinmin16inToilet centerline from side wall (min)
centerlineMaxmax18inToilet centerline from side wall (max)

Categories

AccessibilityBathroom

Applies to

  • Room types: bathroom, half_bath
  • When:
    • aspires to visitability / universal design

Source

HUD (US Department of Housing and Urban Development)no manifest entry
Fair Housing Act Design Manual (1998 revised)
Section: Chapter Six §6.4
Published 1998-08-01 · last verified 2026-05-10

Solver enforcement

Browsable only — the solver does not currently enforce this directive (no spec-level data to check against). This entry exists so the architect personas can cite it in conversation and the user can read what the rule says.

Related directives

Last reviewed 2026-05-10.